Seven, the transplanting machine seedling spacing is not the same

In the process of actual rice transplanting, if the seedlings are uneven and the distance between the rows of seedlings is inconsistent, it may be related to the following five aspects:

First, there may be inconsistencies in the water content in the soil of the seedling bed;

Second, there may be a large difference in the tension of the vertical delivery;

The third may be the difference in the adjustment of the needles;

The fourth may be the push-pull cam, the fork shaft, the fork and the like of each implant arm. The degree of wear is different;

The fifth is that the chain boxes are not on the same level.

For these faults, while using the corresponding exclusion measures to eliminate, it is also possible to adjust the partial twisting machine one by one, and keep the vertical feeding stroke between 11 and 12 mm; Strict calibration is performed to keep it at the same level; if the fault cannot be eliminated, the worn device must be replaced.
8 Row Rice Transplanter18 Row Rice Transplanter2

Eight, the transplanter pusher is uneven

In the process of actual rice transplanting, if there is a phenomenon that the pusher is not uniform, it may be related to the following points:

First, it may be a guide sleeve, a pusher, a fork, a separation tip and a cam. The wear is too heavy;

secondly, it may be that the push spring is broken;

thirdly, the bolt may be loosened;

fourthly, the pressure of the pressure plate groove may be serious;

fifth, it may be the lower shaft of the connecting rod and the lower shaft of the swing rod damaged badly by Rub.

The main measures are: replace the swing rod and the connecting rod shaft, re-adjust the amount of the picking and tighten the adjusting bolt, or replace the worn parts.

Nine, the transplanter‘s depth adjustment is out of control

In the actual rice transplanting machine, if there is a phenomenon of failure of the transplanting depth adjustment, it may be related to the serious wear of the fixed pin hole, the broken pin seat, and the lifting nut of the rice transplanter or the slider of the lifting rod. For these faults, the pinning seat should be welded in time, or the pin, lifting nut, lifting rod, etc. should be replaced.