Insufficient spray pressure of the sprayer, poor atomization: If the water ball valve is lifted by the dirt, the inlet valve can be removed and the dirt can be removed with a cloth; if the cup is damaged, the new cup can be replaced; If the seal is installed, or the seal is damaged due to damage to the seal, the seal can be added or replaced.
The sprayer does not spray fog: if the inclined hole of the nozzle body is blocked by dirt, the oblique hole can be dredged; if the cleaning nozzle hole can be disassembled due to the nozzle hole blockage, the hard object hole such as wire or copper needle can not be used to prevent the hole Enlargement, the quality of the spray is deteriorated; if the filter in the casing is clogged or the ball of the over-water valve is put up, the filter should be cleaned and the dirt on the ball should be cleaned.
Sprayer2Sprayer3
The sprayer switch leaks or does not move: If the switch cap is not tightened, tighten the switch cap; if the washer on the switch core wears, replace the washer; the switch does not move, because it is placed for a long time, or used for too long, The switch core is adhered by the etch of the agent, and the parts should be removed for cleaning in kerosene or diesel oil; when it is difficult to remove, it can be immersed in kerosene for a period of time, and then removed and removed, and hard objects cannot be used.
Leakage at each joint of the sprayer: If the joint is loose, tighten the nut; if the washer is not flattened or damaged, the washer should be flattened or the gasket replaced; if the gasket is hardened by shrinkage, it can be soaked in animal oil before it is softened. use.