五、插秧机积累
In the process of feeding rice transplanting machine, if there is a phenomenon of accumulation of sputum at the cardia and failure to slide properly, it may be:
首先,由于插秧机的爪部磨损,导致爪部末端不对齐或分离。宽或太窄,以及苗床土层太厚等因素,导致无法正常取苗。遇到这种情况,应及时更换新钳口或修正钳口间距,调整至标准范围。
Second, because the rice transplanter is too tight or too low, the position of the rice transplanter should be readjusted. Finally, because the block is too dry, it should be sprinkled with a proper amount of water on the block to maintain its humidity.
六、插秧机间歇输送
During the rice transplanting machine, the rice transplanting machine is prone to the intermittent or non-working phenomenon. The case where the rice transplanter intermittently works may be related to the weaker elastic force of the feeding cam return spring or the peach-shaped wheel return spring, thereby causing the feeding cam or the peach wheel to fail to return normally.
插秧机不工作的原因比较复杂:一可能是桃形轮定位键损坏或缺失;二是可能是桃形轮定位键损坏或缺失。二是可能是送料轮与桃形轮卡住;最后,可能是凸轮线缺失或断线。
排除方法是打开工作驱动器盖,拆下两个回位弹簧,安装新的回位弹簧。如果两轮出现相位差,就是桃形轮和送料磨损造成的。此时应将桃形轮或送料轮拆下,用镘刀将工作表面抹平;若磨损严重,应更换;如果出现插针或按键现象,则应更换新器件。